The G range draws free energy directly from the ground, using horizontal collectors or vertical probes, for outputs from 8 to 14 kW for the smaller models and 16 to 32 kW for the larger ones, with one or two compressors. Twin-compressor models adapt their output to heating needs, limiting the number of operating cycles for greater savings and durability. For lower outputs, see our Mini-Géo range.

Contact us
G & GT G & GT G & GT

Why choose G & GT?

  • Powerful

    The G range comes with one or two compressors: it covers a wide range of needs and can optionally provide domestic hot water or cooling in summer. Up to 4 units can be installed in cascade for commercial buildings or large installations.

  • Versatile

    The G range can be installed on any type of system (with or without a buffer tank, underfloor heating, radiators, swimming pool…). The controller, developed entirely by our team, can manage up to 10 different heating zones.

  • Quiet

    Its insulated casing and a refrigerant circuit mounted on an oscillating plate with silentblocs make the G range very discreet (around 50 dB).

  • Connected

    Like all VIVRECO heat pumps, the G range features WebControl technology, so it can be controlled from anywhere with a simple Internet connection, through a dedicated space in a mobile app. Our after-sales service is alerted directly in the event of a fault.

  • Special functions

    The VIVRECO controller fitted to the G range can manage a back-up heating system or a domestic hot water loop, keeping the water hot even when there is a long run between the tank and the tap.

  • Long-lasting

    VIVRECO is committed to building sturdy, durable and repairable heat pumps, for genuine sustainability and greater savings. The G range casing is made of powder-coated electro-galvanised steel.

G & GT

Key figures

GT models are the twin-compressor versions. For even higher outputs, larger ranges are available on request: contact us.

Scroll the table sideways to see every model.

Model G 8-V5 S G 10-V5 S G 11-V5 S G 14-V5 S G 8-V5 T G 10-V5 T G 11-V5 T G 14-V5 T G 16-V5 T
Power supply (V) 230V 1~230V 1~230V 1~400V 3~400V 3~400V 3~400V 3~400V 3~400V 3~
Warm climate · ETAS ηs (%) high temperature 156159157160156159157160161
Warm climate · ETAS ηs (%) low temperature 196199197200196199197200202
Average climate · ETAS ηs (%) high temperature 154156154157154156154157158
Average climate · ETAS ηs (%) low temperature 194197195198194197195198199
Cold climate · ETAS ηs (%) high temperature 155157155158155157155158158
Cold climate · ETAS ηs (%) low temperature 197200198201197200198201202
Heat output (kW) at B0/W35 (collector -3/0, heating 30/35) 7.269.110.45–7.159.0810.212.812.8
Dimensions W x H x D (mm) 540 x 1200 x 530
Weight (kg) 135145145135145145160165165
Model G 28-V5 T G 34-V5 T G 40-V5 T G 46-V5 T GT 16-V5 S GT 20-V5 S GT 22-V5 S GT 16-V5 T GT 20-V5 T GT 22-V5 T GT 28-V5 T GT 32-V5 T
Power supply (V) 400V 3~400V 3~400V 3~400V 3~230V 1~230V 1~230V 1~400V 3~400V 3~400V 3~400V 3~400V 3~
Warm climate · ETAS ηs (%) high temperature 150154154151157159157157159157160161
Warm climate · ETAS ηs (%) low temperature 188194188186197200198197200198201202
Average climate · ETAS ηs (%) high temperature 148152152149155157155155157155158158
Average climate · ETAS ηs (%) low temperature 186191186184195198198195198198199200
Cold climate · ETAS ηs (%) high temperature 148152152149155157155155157155158159
Cold climate · ETAS ηs (%) low temperature 188193188186198200196198200196201202
Heat output (kW) at B0/W35 (collector -3/0, heating 30/35) 26.431.738.643.714.5218.219.6814.318.1620.425.630.2
Dimensions W x H x D (mm) 760 x 1130 x 610
Weight (kg) 185195200210210215220210215220230230